The miniature Scanner Digitizing Interface (mSDI) is the connection point for the pressure scanner's cable, providing power to the scanner, stimulating feedback measurements, and performing analog-to-digital A/D at high speeds. mSDI is small in size and low in power consumption, making it ideally suited for mounting in a wind tunnel. Its cross-sectional area is comparable to that of the ESP-64HD scanner, allowing the mSDI to be placed in a row with the pressure scanner for maximum channel density.
Physical Specification | |||
Parametric | mSDI | Units | Comment |
Capacity | 1-4 | Units | Expansion via Ethernet |
Condition | |||
Operating temperature | -25 to 80 | °C | |
Storage temperature | -25 to 100 | °C | |
Relative humidity | 5-95 | % | Non-Condensing |
Vacuum & Pressure | 0.0002 to 150 | PSI Absolute | |
Vibration | 10 | g at 15 to 2000Hz | |
Impact | 30 | g Peak | |
Sealant | IP-50 | ||
Connect | |||
Electrical input | From RPS | ||
Electrical output | To ESP | ||
Fiber optic | To OFIU | ||
Aerodynamic | N/A | ||
Power supply | |||
Power input | From RPS | Volts AC | 50 or 60 Hz |