Optimus
Product Description
The Optimus System Processor manages a configurable measurement solution that provides high precision and throughput data for up to 2048 measurement channels.
Pressure is measured with ESP Miniature Pressure Scanners or the new MicroScanners, and then converted to a digital value within the Miniature Scanner Digitizer Interface (mSDI) units. Engineering Unit measurement values are calculated within the Optimus System Processor and reported via Ethernet at data rates up to 1GBit/second. Users preferring to calculate engineering unit data in their own host computer can receive measurement values in binary format via the Ethernet interface.
Key Features
Direct placement within model
Transient data information
Highest industry accuracy
Stable readings
Fast, accurate calibration & verification
Minimizes cable load on force balance
Preserves previous hardware & software investment
ESP Pressure Scanner Compatible
Up to +/- 0.03% Accuracy
Up to 2000 Hz/port EU Data Throughput
DTC Digital Temperature Compensation
Miniature Scanner Digitizing Interface
8400 System Command Compatibility
Applications
Wind Tunnel Testing
Aeronautical development tests
Physical Specification | ||||||||||
Parameter | OSP | OFIU | mSDI | RPS | PCU | RP | PBU | ESP | Units | Comment |
Capacity | 1 | 1-4 | 1-4 | 1-4 | 1-12 | 1-3 | 6 max required | 1-32 | Units | Expansion via Ethernet |
Condition | ||||||||||
Operating temperature | 0-50 | 0-50 | -25 to 80 | 0-50 | 0-50 | 0-50 | 0-50 | -25 to 80 | °C | |
Storage temperature | 0-80 | 0-80 | -25 to 100 | 0-80 | 0-80 | 0-80 | 0-80 | -25 to 100 | °C | |
Relative humidity | 5-95 | 5-95 | 5-95 | 5-95 | 5-95 | 5-95 | 5-95 | 5-95 | % | Non-Condensing |
Vacuum & Pressure | 10-16 | 10-16 | 0.0002 to 150 | 10-16 | 10-16 | 10-16 | 10-16 | 0.0002 to 150 | PSI Absolute | |
Vibration | N/A | N/A | 10 | N/A | N/A | N/A | N/A | 10 | g at 15 to 2000Hz | |
Impact | N/A | N/A | 30 | N/A | N/A | N/A | N/A | 30 | g Peak | |
Seal up | IP-20 | N/A | IP-50 | IP-20 | IP-40 | IP-20 | IP-50 | IP-40 | ||
Connect | ||||||||||
Electrical input | AC | Internal from OSP | From RPS | AC | Internal to RP | AC | N/A | From mSDI | ||
Electrical output | Ethernet & RS-485 | Internal to OSP | To ESP | To mSDI | Internal to RP | RS-485 to OSP | N/A | To mSDI | ||
Fiber optic | via OFIU | To mSDI | To OFIU | N/A | N/A | N/A | N/A | N/A | ||
Aerodynamic | N/A | N/A | N/A | N/A | Internal to RP | To ESP | Seals Unused RP Slots | Measurements from model & Cal via RP/PCU | ||
Power supply | ||||||||||
Power Input | Universal 100-240 | Internal from OSP | From RPS | Specified 100, 110, 220 | From RP | Specified 100, 110, 220 | N/A | From mSDI | Volts AC | 50 or 60 Hz |